This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
x40:firmware [2020/10/23 15:37] peter |
x40:firmware [2021/08/16 10:51] (current) peter |
||
---|---|---|---|
Line 2: | Line 2: | ||
====Machine Firmware==== | ====Machine Firmware==== | ||
+ | |||
+ | ===X40 V1.2.0=== | ||
+ | 1. Add the Baby Z offset in the printing interface, you can set baby Z offset when you printing.\\ | ||
+ | {{: | ||
+ | 2. Add the dual Nozzle switch function in the printing interface.\\ | ||
+ | {{: | ||
+ | 3. Add the function that: when the runout sensor trigger, the printing extruder will switch to another extruder\\ | ||
+ | 4. Add the Y direction '' | ||
+ | 5. Fixed an issue where bias parameters could not be saved.\\ | ||
+ | 6. Fixed the problem of abnormal start-up and continuous call.\\ | ||
+ | 7. Fixed an issue where there was no push message after the printing was completed.\\ | ||
+ | 8. Fixed the problem of the unlimited position of the switch in Jog mode.\\ | ||
+ | 9. Fixed the problem that the missing material wire will be reported if there is no material wire in the extruder on the other side when printing the single sprinkler model.\\ | ||
+ | 10. Fixed the problem that the left sprinkler returned to the drawing wire after the execution of the G28 instruction.\\ | ||
+ | 11. Fixed an issue where you can't continue to print in copy and mirror mode.\\ | ||
+ | 12. Fixed a problem where the right extruder did not return to position after printing was paused in copy and mirror mode.\\ | ||
+ | 13. Fixed an issue where the right fan started abnormally when the left fan was started in automatic docking mode.\\ | ||
+ | 14. Fixed an issue where the X coordinate offset was not reset after copying and mirroring mode printing.\\ | ||
+ | |||
+ | <WRAP center round download 30%> \\ | ||
+ | [[https:// | ||
+ | </ | ||
+ | |||
+ | |||
+ | ===X40 V1.1.2=== | ||
+ | 1. Fixed an issue where the zoffset parameters were emptied after the factory settings were restored.\\ | ||
+ | 2. Modify the prompt message for height adjustment of double sprinklers.\\ | ||
+ | 3. Fixed the problem that there is no prompt message in the adjustment interface of the proximity switch.\\ | ||
+ | 4. Increase the position of the sprinkler in the X direction before resuming printing.\\ | ||
+ | 5. When printing a WiFi disk file, clicking Settings will display a prompt that the parameters cannot be set.\\ | ||
+ | |||
+ | < | ||
+ | [[https:// | ||
+ | </ | ||
+ | |||
+ | |||
+ | ===X40 V1.1.1=== | ||
+ | |||
+ | < | ||
+ | [[https:// | ||
+ | </ | ||
+ | |||
===X40 V1.1.0=== | ===X40 V1.1.0=== | ||
- | 1. When modifying the sprinkler | + | 1. When modifying the nozzles |
- | 2. Double | + | 2. Double |
- | 3. The waiting time of 2 seconds after entering the wire when the double sprinkler | + | 3. The waiting time of 2 seconds after entering the filament |
- | 4. Fixed the problem that the automatic | + | 4. Fixed the problem that the automatic |
- | 5. Fixed the problem that the extruder motor was locked after the automatic entry and exit wire. | + | 5. Fixed the problem that the extruder motor was locked after the automatic entry and exit filament.\\ |
- | 6. Fixed an issue where the shutdown could not be saved. | + | 6. Fixed an issue where the shutdown could not be saved.\\ |
- | 7. Fixed the problem of continuous call due to power outage. | + | 7. Fixed the problem of continuous call due to power outage.\\ |
- | 8. Fixed the problem that Chinese documents could not be printed. | + | 8. Fixed the problem that Chinese documents could not be printed.\\ |
- | 9. Fixed incorrect display of keys in the WiFi disk file preview interface | + | 9. Fixed incorrect display of keys in the WiFi disk file preview interface\\ |
< | < | ||
Line 28: | Line 70: | ||
</ | </ | ||
- | ====UI For X40==== | + | ====UI |
< | < |