| + | **2.Hotend PID Tuning**\\ | ||
| + | |||
| + | Get the current PID settings using the M503command. Your printer will return the current PID settings. | ||
| + | |||
| + | Run the M106 S255 command in order to set your cooling fan to 100% | ||
| + | |||
| + | Run the M303 E0 S215 C8 command and wait for the process to finish. | ||
| + | |||
| + | ---- | ||